Difference between revisions of "Gas Spec Issues(TEG)"
From FNNC
(Created page with "If the water content of the gas leaving the TEG dehydration process exceeds sales specifications, the following areas should be investigated: *insufficient TEG regeneration: :...") |
(No difference)
|
Latest revision as of 10:21, 29 June 2018
If the water content of the gas leaving the TEG dehydration process exceeds sales specifications, the following areas should be investigated:
- insufficient TEG regeneration:
- -insufficient stripping steam/reboiler heat input?
- -incorrect TEG recovery from TEG drain tank—too much water-laden TEG pumped to TEG reboiler?
- -incorrect TEG stripping column pressure?
- -contaminated or degraded TEG?
- -plugged TEG stripping column packing?
- -too low a TEG flow through TEG stripping column?
- -insufficient stripping (fuel) gas admitted to the small supplementary stripper?
- insufficient TEG circulation rate:
- -TEG pump speed too low?
- -TEG pump bypass lines open or passing pump bypass valves?
- -low level in TEG accumulator?
- different operating conditions:
- -lean TEG entering contactor too hot?
- -too high a gas flow through contactor?
- -higher water content in the incoming gas?
- -low TEG contactor pressure?